Ja juz tam jestem jakiś czas zalogowany :-D Oto dwie instrukcje odnalezione na tej stronce. "SRI-18 Programmable Output Expander Module" Installation Manuals English - 960429 (PDF: 1.4 MB / 10 pages) English - IM-SR1-18 970616-0003 (PDF: 88 KB / 15 pages) http://obrazki.elektroda.net/64_1206554245.jpg


Programmable Output Module
Installation Manual

PROGRAMMING CODE: (4 digits) (default = 1818)
To enter programming mode, press [ENTER] + programming code
ADDRESS 000: 1 / 8
ADDRESS 001: 1 / 8

HOW TO:

FEATURE SELECT (LIGHT ON/OFF) PROGRAMMING

Feature selection programming addresses 002 to 008. The " ON " / " OFF " status of the lights (keys) determines features selected.
1) Press [ENTER] + installer code (default 1818), [ENTER] key will flash.
2) Enter 3 digit memory address (002 to 008).
3) Press corresponding key to select option.
4) To change selection press key again.
5) To save press [ENTER].
6) Repeat steps 3 to 5 for addresses 002 to 008.
7) To exit programming mode press [CLEAR].

OUTPUT TYPES: (default =

)

ADDRESS 002

ADDRESS 004

OFF

ON

OFF

EVENT / [KEY] / TIMER

PGM
PGM
PGM
PGM
PGM
PGM
PGM
PGM

OFF

EVENT / [KEY] / TIMER

[3]
[2]
[1]
[2ND]
[6]
[5]
[4]
[TRBL]

1
2
3
4
5
6
7
8

ON

PGM
PGM
PGM
PGM
PGM
PGM
PGM
PGM

[9]
[8]
[7]
[MEM]
[12]
[11]
[10]
[BYP]

9
10
11
12
13
14
15
16

ON

EVENT / [KEY] / TIMER

[3]
[2]

RLY 1
RLY 2

NOTE: When key light is " OFF " , deactivation occurs as a result of an EVENT. When light is " ON " , deactivation occurs following TIMER EXPIRATION.

DEACTIVATION TYPES: (default =

)

ADDRESS 006
OFF
OR /

PGM
PGM
PGM
PGM
PGM
PGM
PGM
PGM

1
2
3
4
5
6
7
8

ADDRESS 008
[KEY]

[3]
[2]
[1]
[2ND]
[6]
[5]
[4]
[TRBL]

ON

OFF

/ AND

OR /

PGM
PGM
PGM
PGM
PGM
PGM
PGM
PGM

9
10
11
12
13
14
15
16

[KEY]

[9]
[8]
[7]
[MEM]
[12]
[11]
[10]
[BYP]

ON

OFF

/ AND

OR /

RLY 1
RLY 2

NOTE: When key light is " OFF " , deactivation depends on " OR " logic. When light is " ON " , deactivation depends on " AND " logic.
( " EVENT " must be selected at address 002 or 004 as required.)

4

[KEY]

[3]
[2]

ON

/ AND

HOW TO:

3 DIGIT DECIMAL VALUE PROGRAMMING

Decimal value programming addresses 010 to 063. Values entered must contain 3 digits.
1) Press [ENTER] + installer code (default 1818), [ENTER] key will flash.
2) Enter 3 digit address (010 to 063).
3) Enter 3 digit DECIMAL value.
4) To exit, press [CLEAR]. To save press [ENTER].
5) Go to step 2 for next address. To exit programming mode press [CLEAR].

Values entered at the 3 consecutive addresses corresponding to each PGM are defined as follows:
PGMxx 1st address: First event code of activation range
2nd address: Last event code of activation range
3rd address: First code of deactivation range OR TIMER SETTING

PROGRAMMABLE OUTPUT:
ADDRESS

ADDRESS

010:
011:
012:

1 / 2 / 8 PGM 1 Zone 1 alarm (System A)
1 / 3 / 3 PGM 1 Zone 6 alarm (System A)
1 / 9 / 2 PGM 1 Zone 1 restored (System A)

037:
038:
039:

1 / 5 / 7 PGM 10 Timer loss
1 / 5 / 7 PGM 10 Timer loss
2 / 2 / 1 PGM 10 Timer loss restored

013:
014:
015:

1 / 6 / 0 PGM 2 Zone 7 alarm (System B)
1 / 6 / 5 PGM 2 Zone 12 alarm (System B)
2 / 2 / 4 PGM 2 Zone 7 restored (System B)

040:
041:
042:

0 / 6 / 2 PGM 11 TLM: panel
0 / 6 / 2 PGM 11 TLM: panel
2 / 2 / 3 PGM 11 TLM: panel restored

016:
017:
018:

0 / 6/ 4 PGM 3 Armed by User 1 (System A)
0 / 7 / 1 PGM 3 Armed by User 8 (System A)
0 / 8 / 0 PGM 3 Disarmed by User 1 (System A)

043:
044:
045:

1 / 5 / 8 PGM 12 Fire loop trbl.
1 / 5 / 8 PGM 12 Fire loop trbl.
2 / 2 / 2 PGM 12 Fire loop trbl. restored

019:
020:
021:

1 / 0 / 3 PGM 4 Armed by User 8 (System B)
1 / 1 / 1 PGM 4 Armed by user 16 (System B)
1 / 1 / 9 PGM 4 Disarmed by user 8 (System B)

046:
047:
048:

1 / 8 / 7 PGM 13 Partial arming
1 / 8 / 7 PGM 13 Partial arming
2 / 5 / 3 PGM 13 Disarm A Master

022:
023:
024:

1/5/4
1/5/4
2/1/8

049:
050:
051:

1 / 8 / 4 PGM 14 Panic 1
1 / 8 / 4 PGM 14 Panic 1
0 / 6 / 0 PGM 14 Time

025:
026:
027:

0 / 6 / 0 PGM 6 Midnight
0 / 6 / 0 PGM 6 Midnight
0 / 0 / 1 PGM 6 1 second

052:
053:
054:

1 / 8 / 5 PGM 15 Panic 2
1 / 8 / 5 PGM 15 Panic 2
1 / 2 / 0 PGM 15 Time

028:
029:
030:

1 / 8 / 4 PGM 7 Panic 1 audible
1 / 8 / 4 PGM 7 Panic 1 audible
0 / 6 / 3 PGM 7 Alarm reset

055:
056:
057:

1 / 8 / 6 PGM 16 Panic 3
1 / 8 / 6 PGM 16 Panic 3
1 / 2 / 0 PGM 16 Time

031:
032:
033:

1 / 5 / 2 PGM 8 Max. aux. current trouble
1 / 5 / 5 PGM 8 No AC
2 / 1 / 6 PGM 8 Max. aux. current restored

058:
059:
060:

1 / 2 / 8 RLY 1 Zone 1 alarm report (System A)
1 / 5 / 1 RLY 1 Tamper 18 (748ES) (System A)
2 / 4 / 0 RLY 1

034:
035:
036:

1 / 5 / 5 PGM 9 No AC
1 / 5 / 5 PGM 9 No AC
2 / 1 / 9 PGM 9 AC restored

061:
062:
063:

1 / 6 / 0 RLY 2 Zone 7 alarm report (System B)
1 / 8 / 3 RLY 2 Tamper 24 (748ES) (System B)
2 / 4 / 0 RLY 2

PGM 5 Battery fail
PGM 5 Battery fail
PGM 5 Battery restored

5

PROGRAMMING WORK SHEET
PROGRAMMING CODE: (4 digits) (default = 1818)

To enter programming mode, press [ENTER] + programming code
ADDRESS 000: 1 / 8
ADDRESS 001: 1 / 8

OUTPUT TYPES:
ADDRESS 002
PGM
PGM
PGM
PGM
PGM
PGM
PGM
PGM

OFF

[3]
[2]
[1]
[2ND]
[6]
[5]
[4]
[TRBL]

1
2
3
4
5
6
7
8

DEACTIVATION TYPES:
OFF
ADDRESS 006

[KEY]

OR /

PGM
PGM
PGM
PGM
PGM
PGM
PGM
PGM

ADDRESS 003

ON

EVENT / [KEY] / TIMER

1
2
3
4
5
6
7
8

PGM
PGM
PGM
PGM
PGM
PGM
PGM
PGM

ON

[9]
[8]
[7]
[MEM]
[12]
[11]
[10]
[BYP]

9
10
11
12
13
14
15
16

ADDRESS 007

ON

/ AND

[3]
[2]
[1]
[2ND]
[6]
[5]
[4]
[TRBL]

PROGRAMMABLE OUTPUT:

OFF

EVENT / [KEY] / TIMER

OFF
OR /

PGM
PGM
PGM
PGM
PGM
PGM
PGM
PGM

9
10
11
12
13
14
15
16

[KEY]

ADDRESS 004

OFF

ON

EVENT / [KEY] / TIMER

[3]
[2]

RLY 1
RLY 2

ON

/ AND

[9]
[8]
[7]
[MEM]
[12]
[11]
[10]
[BYP]

*

ADDRESS
010:
011:
012:

/
/
/

/
/
/

PGM 1*
PGM 1
PGM 1

First event code of activation range
Last event code of activation range
First event code of deactivation range OR TIMER SETTING

013:
014:
015:

/
/
/

/
/
/

PGM 2*
PGM 2
PGM 2

First event code of activation range
Last event code of activation range
First event code of deactivation range OR TIMER SETTING

016:
017:
018:

/
/
/

/
/
/

PGM 3
PGM 3
PGM 3

019:
020:
021:

/
/
/

/
/
/

022:
023:
024:

/
/
/

025:
026:
027:

ADDRESS 008

OFF
OR /

[KEY]

[3]
[2]

RLY 1
RLY 2

ADDRESS
037:
038:
039:

ON

/ AND

/
/
/

/
/
/

PGM 10
PGM 10
PGM 10

040:
041:
042:

/
/
/

/
/
/

PGM 11
PGM 11
PGM 11

First event code of activation range
Last event code of activation range
First event code of deactivation range OR TIMER SETTING

043:
044:
045:

/
/
/

/
/
/

PGM 12
PGM 12
PGM 12

PGM 4
PGM 4
PGM 4

First event code of activation range
Last event code of activation range
First event code of deactivation range OR TIMER SETTING

046:
047:
048:

/
/
/

/
/
/

PGM 13
PGM 13
PGM 13

/
/
/

PGM 5
PGM 5
PGM 5

First event code of activation range
Last event code of activation range
First event code of deactivation range OR TIMER SETTING

049:
050:
051:

/
/
/

/
/
/

PGM 14
PGM 14
PGM 14

/
/
/

/
/
/

PGM 6
PGM 6
PGM 6

First event code of activation range
Last event code of activation range
First event code of deactivation range OR TIMER SETTING

052:
053:
054:

/
/
/

/
/
/

PGM 15
PGM 15
PGM 15

028:
029:
030:

/
/
/

/
/
/

PGM 7
PGM 7
PGM 7

First event code of activation range
Last event code of activation range
First event code of deactivation range OR TIMER SETTING

055:
056:
057:

/
/
/

/
/
/

PGM 16
PGM 16
PGM 16

031:
032:
033:

/
/
/

/
/
/

PGM 8
PGM 8
PGM 8

First event code of activation range
Last event code of activation range
First event code of deactivation range OR TIMER SETTING

058:
059:
060:

/
/
/

/
/
/

RLY 1
RLY 1
RLY 1

034:
035:
036:

/
/
/

/
/
/

PGM 9
PGM 9
PGM 9

First event code of activation range
Last event code of activation range
First event code of deactivation range OR TIMER SETTING

061:
062:
063:

/
/
/

/
/
/

RLY 2
RLY 2
RLY 2

6

EVENT CODE LIST 1
TIME

SYSTEM A

Nonreporting
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15

N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U

64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79

16
17
18
19
20
21
22
23

N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U

80
81
82
83
84
85
86
87

24
25
26
27
28
29
30
31

N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U

88
89
90
91
92
93
94
95

SYSTEM A

Armed by
User 1
User 2
User 3
User 4
User 5
User 6
User 7
User 8
User 9
User 10
User 11
User 12
User 13
User 14
User 15
User 16
Disarmed by
User 1
User 2
User 3
User 4
User 5
User 6
User 7
User 8
User 9
User 10
User 11
User 12
User 13
User 14
User 15
User 16

TIME

128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143

32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47

N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U

96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111

48
49
50
51
52
53
54
55

N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
(System A/B)
N/U
N/U
N/U
N/U
Midnight
Fail to comm.
TLM: panel
Alarm Reset

112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127

Zone restore reports
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
N/U
N/U
N/U
N/U
N/U
N/U
Zone 13
Zone 14
Zone 15
Zone 16

208
Zone 17
209
Zone 18
210
N/U
211
N/U
212
N/U
213
N/U
214
N/U
215
N/U
Trouble restored (System A/B)
216
Max. aux. current
217
Max. bell current
218
Batt. fail
219
No AC
220
Tamper/wiring
221
Timer loss
222
Fire loop trbl
223
TLM: panel

SYSTEM B

Zones restore
Zone 7
Zone 8
Zone 9
Zone 10
Zone 11
Zone 12
N/U
N/U
N/U
N/U
N/U
N/U
Zone 19
Zone 20
Zone 21
Zone 22

Zone 23
Zone 24
Tamper 19 (748ES)
Tamper 20 (748ES)
Tamper 21 (748ES)
Tamper 22 (748ES)
Tamper 23 (748ES)
Tamper 24 (748ES)

184
185
186
187
188
189
190
191

7

Alarm reports
Zone 7
Zone 8
Zone 9
Zone 10
Zone 11
Zone 12
Tamper 7
Tamper 8
Tamper 9
Tamper 10
Tamper 11
Tamper 12
Zone 19
Zone 20
Zone 21
Zone 22

176
177
178
179
180
181
182
183

User 9
User 10
User 11
User 12
User 13
User 14
User 15
User 16

SYSTEM B

160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175

Armed by
User 1
User 2
User 3
User 4
User 5
User 6
User 7
User 8
User 9
User 10
User 11
User 12
User 13
User 14
User 15
User 16
Disarmed by
User 1
User 2
User 3
User 4
User 5
User 6
User 7
User 8

56
57
58
59
60
61
62
63

192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207

144
Zone 17
145
Zone 18
146
Tamper 13 (748ES)
147
Tamper 14 (748ES)
148
Tamper 15 (748ES)
149
Tamper 16 (748ES)
150
Tamper 17 (748ES)
151
Tamper 18 (748ES)
Trouble reports (System A/B)
152
Max. aux. current
153
Max. bell current
154
Batt. fail
155
No AC
156
Program Change
157
Timer loss
158
Fire loop trbl.
159
Test report

SYSTEM B

Nonreporting

SYSTEM A

Alarm reports
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Tamper 1
Tamper 2
Tamper 3
Tamper 4
Tamper 5
Tamper 6
Zone 13
Zone 14
Zone 15
Zone 16

Panic 1
Panic 2
Panic 3
Partial arming
Arm A Espload
Arm A Master
Arm B Espload
Arm B Master

224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239

240
Zone 23
241
Zone 24
242
N/U
243
N/U
244
N/U
245
N/U
246
N/U
247
N/U
SPECIAL (System A/B)
248
No movement
249
N/U
250
N/U
251
N/U
252
Disarm A Espload
253
Disarm A Master
254
Disarm B Espload
255
Disarm B Master

EVENT CODE LIST 2
TIME

SYSTEM A

Nonreporting
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15

N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U

64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79

16
17
18
19
20
21
22
23

N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U

80
81
82
83
84
85
86
87

24
25
26
27
28
29
30
31

N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U

88
89
90
91
92
93
94
95

SYSTEM A

Armed by
User 1
User 2
User 3
User 4
User 5
User 6
User 7
User 8
User 9
User 10
User 11
User 12
User 13
User 14
User 15
User 16
Disarmed by
User 1
User 2
User 3
User 4
User 5
User 6
User 7
User 8
User 9
User 10
User 11
User 12
User 13
User 14
User 15
User 16

TIME

128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143

32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47

N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U

96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111

48
49
50
51
52
53
54
55

N/U
N/U
N/U
N/U
N/U
N/U
N/U
N/U
(System A/B)
N/U
N/U
N/U
N/U
Midnight
Fail to comm.
TLM: panel
Alarm Reset

112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127

Zone restore reports
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Zone 9
Zone 10
Zone 11
Zone 12
Zone 13
Zone 14
Zone 15
Zone 16

208
N/U
209
N/U
210
N/U
211
N/U
212
N/U
213
N/U
214
N/U
215
N/U
Trouble restored (System A/B)
216
Max. aux. current
217
Max. bell current
218
Batt. fail
219
No AC
220
Tamper/wiring
221
Timer loss
222
Fire loop trbl
223
TLM: panel

SYSTEM B

Zones restore
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Zone 9
Zone 10
Zone 11
Zone 12
Zone 13
Zone 14
Zone 15
Zone 16

Tamper 1
Tamper 2
Tamper 3
Tamper 4
Tamper 5
Tamper 6
Tamper 7
Tamper 8

184
185
186
187
188
189
190
191

8

Alarm reports
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Zone 9
Zone 10
Zone 11
Zone 12
Zone 13
Zone 14
Zone 15
Zone 16

176
177
178
179
180
181
182
183

User 9
User 10
User 11
User 12
User 13
User 14
User 15
User 16

SYSTEM B

160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175

Armed by
User 1
User 2
User 3
User 4
User 5
User 6
User 7
User 8
User 9
User 10
User 11
User 12
User 13
User 14
User 15
User 16
Disarmed by
User 1
User 2
User 3
User 4
User 5
User 6
User 7
User 8

56
57
58
59
60
61
62
63

192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207

144
Tamper 1
145
Tamper 2
146
Tamper 3
147
Tamper 4
148
Tamper 5
149
Tamper 6
150
Tamper 7
151
Tamper 8
Trouble reports (System A/B)
152
Max. aux. current
153
Max. bell current
154
Batt. fail
155
No AC
156
Program Change
157
Timer loss
158
Fire loop trbl.
159
Test report

SYSTEM B

Nonreporting

SYSTEM A

Alarm reports
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Zone 9
Zone 10
Zone 11
Zone 12
Zone 13
Zone 14
Zone 15
Zone 16

Panic 1
Panic 2
Panic 3
Partial arming
Arm A Espload
Arm A Master
Arm B Espload
Arm B Master

224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239

240
N/U
241
N/U
242
N/U
243
N/U
244
N/U
245
N/U
246
N/U
247
N/U
SPECIAL (System A/B)
248
No movement
249
N/U
250
N/U
251
N/U
252
Disarm A Espload
253
Disarm A Master
254
Disarm B Espload
255
Disarm B Master

CONNECTION DIAGRAMS
Powered by control panel

SERIAL PORT
FROM PANEL

J2

TO OTHER
MODULES

RESET

J3

AUX

+

AUX GRN YEL

-

KEYPAD

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

N.O. COM N.C.

N.O. COM N.C.

RLY#1

RLY#2

PANEL AUX +
PANEL AUX -

CONTROL RELAY
(IF NECESSARY)

KEYPAD

RED
BLK
GRN
YEL

(Required for programming
only)
CONNECT AUXOF AUXILIARY POWER
SUPPLY TO AUXOF SRI-18

AUXILIARY POWER

Powered by external power supply

SERIAL PORT
FROM PANEL

J2

TO OTHER
MODULES

RESET

J3

AUX

+

AUX GRN YEL

-

KEYPAD

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

N.O. COM N.C.

N.O. COM N.C.

RLY#1

RLY#2

CONTROL RELAY
(IF NECESSARY)

KEYPAD

RED
BLK
GRN
YEL

(Required for programming
only)

AUXILIARY POWER

780 Industrial Blvd., St-Eustache, Montreal, Quebec, Canada J7R 5V3 Fax: (514) 491-2313

CONNECT AUXOF AUXILIARY POWER
SUPPLY TO AUXOF SRI-18

Paradox Security Systems Graphic Dept
PRINTED IN CANADA
960429