Wykaz domofonów zawierający foto domofonu, jego wnętrze i schemat podłączenia, załączniki w formacie PDF, alfabetycznie poukładane! http://obrazki.elektroda.pl/7371071500_1391254646_thumb.jpg Wykaz alfabetyczny: ACET 701 ORIGINAL (5 Wire) ACET 701 (5 WIRE) ACET 702 ORIGINAL (2 WIRE) ACET 702 (2 WIRE) ACET 22500 (5 WIRE) ACET 22220 (2 Wire) ACET 22220 (2 Wire) NEW VERSION 2011 ACET 22510 (5 Wire Ellisse Kit Handset) AIPHONE VC-K AMPLYVOX AMPLYVOX Symbol 2215 ATEA 702 AUDIO BRAND AUTA K80 BELL SYSTEM (BSTL) OLD 801 BELL SYSTEM (BSTL) NEW 801 BELL SYSTEM (BSTL) NEW 801 PS (PRIVACY) BELL SYSTEM (BSTL) BC 801 (Bell-call System Handset) BELL SYSTEM (BSTL) SERIES 500 (DC CALL) BELL SYSTEM (BSTL) BS-LX BITRON AN 0002 BITRON SERIES 70 BITRON AN9102 (4 + n with tone call) BITRON AN9102/RZ (4 + n with Buzzer Call) BITRON AV 1407 / 001 4+n BITRON AV 1407 / 002 1+n BITRON AV 1407 / 010 T-LINE UNIVERSAL (Grothe HT-623) BPT C-200 BPT AS C/200 (Later Model) BPT YC-200 (Basic 4 Wire Systems) BPT YC-300 (System 300 X1(2 Wire) BPT XC-201 BPT YC-200 BTICINO 344202 SPRINT (2 Wire) BTICINO 334202 SPRINT OLD STYLE (5 Wire) BTICINO 334202 SPRINT (5 Wire) CARETAKER GDS1 (Caretrend) (Council Systems) COMELIT VOX 2000 (2 Wire) COMELIT VOX 2000 (5 Wire) COMELIT OK 2404W COMELIT 2628 Style COMELIT Style 2603u BASIC (Universal) COMELIT Style 2602u (Universal) DAITEM Analogue Wireless Handset DAITEM Digital Wireless Handset ELVOX 801 Series ELVOX 8870 ELVOX 8875 (Electronic Call) ELVOX 8877 (Digi-Bus) ELVOX 900 ELVOX 620R/1 ELVOX 6200 (Electronic Call) ELVOX 6204/1 (For Digi-Bus) ELVOX 6220A (For Digit 2 Wires) ENSIGN 3406 (Council Systems) ENSIGN 3407 (Council Systems) ENTROTECH ED4 (Council Systems) ENTROTECH ED4 + (Council Systems) ENTRYPHONE 5901 Legacy ENTRYPHONE 8022 ENTRYPHONE 201 ENTRYPHONE 202 FAKE BPT YC-200 FARFISA 724N FARFISA 924W FARFISA PT510W FARFISA PT511 SW/1 FERMAX NR-0104 FERMAX 2001 (UNIVERSAL) FERMAX 2044 FERMAX 2049 FERMAX CITYMAX 8044 (Basic) FERMAX LOFT 3393 (4+n) FERMAX CITYMAX 8039 (UNIVERSAL) FERMAX LOFT 3399 (UNIVERSAL) FERMAX LOFT BUS 2 FERMAX LOFT VDS GDX AUDIO HANDSET (GDX5 2B Phone) GDX AUDIO APARTMENT STATION (GDX5 3B Audio Apt Stn) GOLMAR T812/DP GOLMAR T-700 GOLMAR T-710R PLATEA (UNIVERSAL) ISM 2600/NIDT (Council Systems) ISM 2404/NIDT (Council Systems) ISM 2450/NIDT (Council Systems) KALLGLOBE TN-5HK LT TERRANEO 603 (Original) LT TERRANEO 603n LT TERRANEO 603n later model (white) LT TERRANEO 603.2 (2 WIRE) LT TERRANEO 600 (Beige) LT TERRANEO 600 (White) LT TERRANEO PH620WS LT TERRANEO 334002 (4+n) SCHOONER STATUS (SML 1130/T) AC Call (Council Systems) STATUS (SML 5800/DC) Electronic Call (Council Systems) STATUS (SML 1131/DC) Electronic Call (Council Systems) STATUS 5800/NID AC CALL (Council Systems) STATUS (SML 1130/NID) AC CALL (Council Systems) STATUS (SML 1131/NID) Electronic Call (Council Systems) STATUS (SML AT-PID) Electronic Call (Council Systems) STATUS (SML MAT-2C) Electronic Call (Council Systems) STR HT 2003/2W STR HT 3003/2W TECHNIPHONE TN-5HZ TECHNIPHONE TN-5HK TEGUI T-71E TYNETEC (Council Systems) TYNETEC ZFT 290 TYNETEC ENTEL 300 URMET Super Jolly URMET 730 (AC Call) URMET 1030 (AC Call) URMET 1130 (AC Call) URMET 1131 (Electronic Call) URMET 1132 (Electronic Call) URMET 1133 Atlantico (Electronic Call) URMET 1138/3 (For DIGI-VOICE Systems) URMET 1140/1 SIGNO (Electronic Call) VIDEX 524 VIDEX 525s VIDEX 924 VIDEX 924 M2L VIDEX 925s (2 Wire) VIDEX 926S VIDEX 3011 SMART VIDEX 3021 (AC Call) VIDEX 3101 VIDEX 3102 VIDEX 3111 (Electronic Call Only) VIDEX 3121 VIDEX 3126 VIDEX 3151 VIDEX 3172 DIGITAL VIDEX 3176
Fermax CityMax 8044 Basic
Terminals
1
2
3
6
4
Lock
Speech Out (Mic)
Common
Speech In (Speaker)
Call
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
Wiring Diagram
1 Way Basic Audio
Wiring Diagram
5 Wire Audio System
Wiring Diagram
5 Wire Audio with 2 Entrances
Fermax 2049
See Connection Diagrams
Below
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
Wiring Diagram
1 Button Panel and 4 intercommunicating handsets
Wiring Diagram
1 Button Panel and 8 intercommunicating handsets
Fermax Loft VDS
Terminals
F1 / F2
+
_
L
A
T
Aux Functions (Neg
Output)
Supply +18VDC
Supply –18VDC
Data & Audio
Extn Call
Local Call (- to T)
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
FARFISA 924W
Terminals
1
2
3
5
6
Speech Out (Mic)
Speech In (Speaker)
Common
Lock
Call
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
WIRING DIAGRAM
2 Entrance Wiring Diagram
Fermax Loft 3393 (4+n)
Terminals
1
2
3
6
4
Lock
Speech Out (Mic)
Common
Speech In (Speaker)
Call
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
Farfisa 724N
Terminals
1
2
3
5
6
Speech Out (Mic)
Speech In (Speaker)
Common
Lock
Call
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
WIRING DIAGRAM
2 Entrance Wiring Diagram
Fermax 2001 Universal
Terminals
1
2
3
6
4
5
Lock
Speech Out (Mic)
Common
Speech In (Speaker)
AC Call
Electronic Call
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
Fermax Universal Compatibility Chart
Wiring Diagram
1 Way Basic Audio
Wiring Diagram
5 Wire Audio System
Wiring Diagram
5 Wire Audio with 2 Entrances
Fermax 2044
Terminals
1
2
3
6
4
Lock
Speech Out (Mic)
Common
Speech In (Speaker)
Call
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
Wiring Diagram
1 Way Basic Audio
Wiring Diagram
5 Wire Audio System
Wiring Diagram
5 Wire Audio with 2 Entrances
Farfisa PT511 SW/1
Terminals
1 Call / Speech / Lock
3 Common
6
7
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
WIRING DIAGRAM
Fermax Citymax 8039 Universal
Terminals
1
2
3
6
4
Lock
Speech Out (Mic)
Common
Speech In (Speaker)
Call
Note : Jumpers must be set correctly
otherwise call tone may not work and you
may only get speech 1 way (see instructions
below)
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
Fermax Universal Compatibility Chart
Instructions modified by Intercoms R us Ltd
Wiring Diagram
1 Way Basic Audio
Wiring Diagram
5 Wire Audio System
Wiring Diagram
5 Wire Audio with 2 Entrances
Farfisa PT510W
Terminals
1
2
3
5
6
Speech Out (Mic)
Speech In (Speaker)
Common
Lock
Call
IMPORTANT NOTE :
1) Before replacing the handset make note of the wires to each terminal on the existing unit (an easy way
is to cut each core off leaving a piece of the insulation in place with colour visible) twist unused cores
together (so you know they are not used, do not short them out).
2) Some older systems will have cable with one coloured core and a solid white core in this case mark
each core with a marker or tape.
3) Some systems may have loop on wiring, you will have 2 cables into your handset (make sure any joins
remain, as these may be serving other flats on the system).
© 2010 www.intercomsrus.com
WIRING DIAGRAM
2 Entrance Wiring Diagram